The SPE20 contains a specialized membrane specifically designed for tough applications such as sampling heavy metals and where porous ceramics are inappropriate.
Applications
· For detection of herbicide, pesticide, and heavy metals
Benefits
· Only materials with sample contact are nylon and polyethylene
· Low sorption
Limits
· Bubble point is 100 kPa, but the porous PE cover allows water to flow only up to 20 kPa
Specifications
SHAFT
|
Ø 2 cm; Acrylic
|
POROUS CERAMIC
|
Ø 2 cm; length 6 cm
|
BUBBLE POINT
|
-100 kPa (only allows water flow up to -20 kPa)
|
SUCTION TUBE
|
PE; Ø 0.16 cm x Ø 0.28 cm
|
PROTECTIVE TUBE
|
PVC, Ø 1.1 cm
|
ACHIEVABLE SAMPLE AMOUNTS
|
Maximum: in free water and with a vacuum of -50 kPa approximately 5 mL per 10 minutes.
Minimum: in sandy loam soil with a vacuum of -50 kPa approximately 5 mL per hour.
|
PORE WATER SAMPLER
|
SK20/SKS20 (Internal Shaft Storage)
|
SIC20/SICS20 (Internal Shaft Storage)
|
SPE20/SPES20 (Internal Shaft Storage)
|
SUCTION CUP MATERIAL
|
Aluminum Oxide Ceramic
|
Silicon Carbide
|
Porous PE-Nylon Cup
|
CHEMICAL SUITABILITY
|
|
|
|
o Anions ( Nitrate, Sulphate, Phosphate, Chloride)
|
Suitable
|
Suitable
|
Suitable
|
o Cations (Calcium, Potassium, Sodium Ammonium)
|
Limited Suitability
|
Suitable
|
Suitable after conditioning and sufficient forerun for flushing.
|
o Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
|
Not Suitable
|
Suitable
|
Suitable
|
o Heavy Metals (Cadmium, Lead)
|
Not Suitable
|
Limited Suitability
|
Suitable
|
*See Chemical Suitability Chart for more information on chemical suitability.
|
BUBBLE POINT
|
100 kPa
|
90 kPa
|
100 kPa (PE cover only allows water flow up to 20 kPa)
|
|